At a glance
Find the two readings taken on the day
Start with any exchange card, label or job record the installer left. Look for the date the meter was changed, the old and new serial numbers, the old meter’s final reading and the new meter’s opening reading. If the record is missing or incomplete, ask your supplier for those details. A photo taken after the visit shows what the new meter read at the time of the photo. The opening reading needs to come from the exchange record.
Keep the last bill before the work and the first one that covers the change. A bill issued after the appointment can still cover an earlier period, so check the billed dates. Photograph the new meter’s serial number and current reading if you can access the meter safely. For help finding the right display and digits, see our gas meter reading guide.
Match each billed reading to the right meter
The layout varies by supplier. You might see two sets of readings on one bill or see the old meter closed on one statement and the new one opened on the next. If the bill only gives a total, ask the supplier to show the two meter records behind it.
- Old meter: match the serial number and the final reading on the bill to the exchange record. Subtract the starting reading for that part of the bill from the final reading.
- New meter: match its serial number and recorded opening reading. Subtract that opening reading from the later reading the supplier used. Use the installation figure even if it was above zero.
- Dates and estimates: check where the old period ends and the new one begins. Ask which readings were estimated and whether any earlier charges were reversed or recalculated. If you see a reading against the wrong serial number, flag that specific line.
Worked example when the old meter was imperial
An older imperial gas meter may record in hundreds of cubic feet, while its replacement measures in cubic metres. In this example the installer removed the old meter at 4860 and recorded 00003 on the new one. Those figures belong to different meters. Calculate each meter’s change in reading in its own units.
| Meter | Start | End | Usage |
|---|---|---|---|
| Old imperial meter | 4852 | 4860 | 8 hundred cubic feet, or 22.64 m³ |
| New metric meter | 00003 | 00023 | 20 m³ |
Multiply by 2.83 for readings in hundreds of cubic feet. Metric readings already give cubic metres.
Check the kWh and the cost
For each part, multiply the cubic metres by the volume correction factor and the calorific value, then divide by 3.6. Take the factors from your bill where shown. With a correction factor of 1.02264 and an illustrative calorific value of 39.5 MJ/m³ for both parts, the old meter accounts for about 254.0 kWh and the new one for 224.4 kWh. Together that’s about 478.4 kWh. Small rounding differences can occur.
At an illustrative 9p per kWh, the usage costs £43.06. If the standing charge is 30p a day for 30 billed days, add £9.00 for a total of £52.06. Both example rates include VAT. If your tariff changed during the bill period, check the usage and rate for each price period. Compare the resulting charges with the bill’s gas charge lines. The amount due can also include an earlier balance or payments already made.
Use the gas bill calculator with each pair of readings to check the usage in kWh. Check the standing-charge days across the whole bill afterwards so the changeover date is counted once. Our guide to converting gas units to kWh explains where to find the figures on your statement.
Ask your supplier to correct the meter record
Send your supplier the exchange date, any installer paperwork, a photo of the new meter and the bill number. Point out the discrepancy, such as the bill treating the new metric meter as imperial. Ask for written confirmation of both serial numbers, the closing and opening readings, which units were used for each meter and a revised bill with a breakdown of the charges. When the revision arrives, compare the corrected readings and check how the original charges were adjusted.
If the supplier can’t resolve the problem, raise a formal complaint and keep the reference. In Great Britain you can take an unresolved complaint to the Energy Ombudsman after eight weeks or sooner if the supplier sends a deadlock letter. See our gas bill complaints guide. In Northern Ireland, contact your supplier first and ask the Consumer Council for help if the issue remains unresolved.
Frequently asked questions
Should my replacement gas meter start at zero?
Use the opening reading recorded at installation. If the bill starts at zero and the exchange record shows another figure, ask the supplier to check the opening reading before it recalculates the bill.
Why is the old gas meter still on my bill?
A bill spanning the exchange may legitimately include usage from both meters. Check the old meter’s billed period and closing reading. If the supplier is still using the old serial for readings taken after the exchange, ask it to reconcile the records.
Can a new smart meter still produce an estimated bill?
Yes. Ask whether the supplier is receiving readings from the new meter and whether the estimate relates to the old meter or the new one. A current reading from the new meter can help correct an estimate for that meter. The old meter’s closing reading is a separate figure.
Sources
Rates and rules checked on 28 November 2026. Time-sensitive figures should be checked again before use.
- GOV.UK — gas meter readings and bill calculation
- Joint Office of Gas Transporters — Uniform Network Code, supply point metering
- Citizens Advice — what to check if your energy bill is too high
- Ofgem — complaints about an energy supplier or network operator
- Consumer Council for Northern Ireland — bills and metering